Histology, the study of how cells are organized
into tissue, is a keystone of the biological sciences. For decades,
histologists have depended upon methods such as the tried-and-true slides
of stained tissue sections. Although much has been learned through these
methods, how much more would be learned if histologists could view tissues
in three dimensions?
Today this advance is becoming a reality thanks
to a newly developed ability to combine ultra–high resolution/microscopic
computed tomography (microCT) scans with high-tech computer protocols
to produce detailed 3-D images of mouse embryos. Besides the marked
advantage of a 3-D perspective, the technique also achieves improvements
in resolution, time required, and costs for studying developmental patterning
effects attributable to genetically engineered mutations and chemically
induced embryotoxicity.
The research team that reported the development
of this method, known as microCT-based virtual histology (MBVH), was
led by Charles Keller, an assistant professor of cellular and structural
biology at the Children's Cancer Research Institute, University
of Texas Health Sciences Center at San Antonio. The innovative technique
was reported in PLoS Genetics in April 2006.
A Better Mouse Sample
Mouse embryos are commonly used to study gene function.
The team's original aim was to develop a method for rapidly assessing
birth defects associated with targeted disruptions of each gene in the
mouse embryo. According to the authors, this called for "systematic,
interdisciplinary approaches to analyzing patterning defects in the
mouse embryo."
What emerged, the authors wrote, was a "novel,
rapid, and inexpensive method for obtaining high-resolution virtual
histology for phenotypic assessment of mouse embryos." Besides
determining how genetic polymorphisms may contribute to end points such
as birth defects and cancer, this new technique can perhaps be used
to assess the safety of new medicines and other chemicals.
The traditional method used in histology is difficult
and time-consuming. Mouse embryos that have genetic mutations or that
have sustained damage from chemicals are killed, embedded in wax, and
sliced into thin sections. Next, they are stained and placed on slides
for microscopic examination. "[The new] technique allows us to
get at a lot more tissues other than bone, such as internal organs,
which [conventional] microCT scans of unstained tissue can't pick
up," says coauthor Chris Johnson, a distinguished professor of
computer science who directs the University of Utah's Scientific
Computing and Imaging Institute.
The technique uses a 1% solution of osmium tetroxide
(OsO4), a major fixative of choice for electron microscopy,
to stain tissues differentially. Images of whole embryos are then made
by volumetric X ray microCT, with as little as 2 hours needed to achieve
isometric resolutions of 27 µm, or 12 hours to achieve resolutions
of 8 µm.
The X ray microCT scans of mouse embryos thus generated
are converted using computer visualization techniques into detailed
3-D images that show the mouse's exterior and interior. Instead
of being physically sliced, the special dyes or fixatives permeate the
skin and other membranes of a mid-gestation embryo; in older embryos
and fetuses, the skin must be removed for the stain to penetrate.
What's in There?
Johnson and his group wrote an algorithm that distinguishes
and visualizes various organs and structures in the mouse embryo based
on the microCT scan data. This produces a virtual rendering of the scan
data that also includes a virtual light source. The 3-D embryo image
can therefore be rendered with shadows, which makes it easier for the
human eye to understand and interpret the image.
The new technique furthermore allows users to create
transparent images or even produce cutaways, so that internal organs
and body parts become visible. Moreover, features as small as 8 µm
can be observed. The purpose is to permit geneticists to examine anatomical
features of large numbers of embryos, each with a different gene disabled.
Then it becomes possible to observe the disruption of normal functions
of many genes faster than by existing methods.
Indeed, with MBVH, scientists can examine as many
as 120 mouse embryos at the same time, each with a different gene knocked
out, to detect a specific defect. In addition, they can observe as many
sets of 120 embryos as needed in order to detect those that require
closer examination at higher resolution—all with the same equipment.
|
The data are in the details. MicroCT scanning of normal (top) and mutated (bottom) mouse embyos allowed researchers to compare effects of the Pax3 gene mutation on the brain and spinal cord that would have been difficult to determine with traditional histology.
image: Isabel Wu/Children's Cancer Research Institute
|
Time is saved, too. The 2 hours it took the research
team to obtain scans of OsO4-stained embryos, with a 27-µm
isometric resolution, is a vast improvement over the tedious techniques
of histological sectioning of early embryos, which needs to be done
with painstaking precision and takes 1 to 3 working days to complete.
Magnetic resonance microscopy has taken some of
the procedural sting out of embryo sample preparation, but it still
requires expensive, specialized equipment. The team was able to use
off-the-shelf specimen scanners, thereby showing that substantial cost
savings are possible—a total cost per scan of $1.50 per embryo
versus $600.00 per embryo with magnetic resonance microscopy.
If higher resolution or increased definition becomes
necessary, a stained embryo can be scanned at a resolution greater than
8 µm. Indeed, a 6-µm resolution has been achieved in the
same time as the 8-µm scan using a different instrument. Keller
and a colleague are now in the process of commercializing the new technique
through their company Numira Biosciences.
MBVH in Practice
For a practical example of how the technique works
for high-throughput phenotyping, the researchers used transgenic mouse
embryos with substantial malformations of the developing brain and upper
spinal cord. Examining these malformations under the dissecting microscope
would have been of little use in determining what structure was what.
"Even light microscope sections were confusing," says Keller.
The microCT scans were what helped the researchers understand which
part of the brain was overgrown and which was underdeveloped as a result
of a Pax3 gene mutation.
These embryos were scanned at a resolution of 27
µm, then rendered to visualize the forebrain, midbrain, and hindbrain
vesicles; the liver; and the heart wall and cardiac vesicles. The complex
3-D organization of the mutated brain sections was made plainly visible.
These views would have been impossible with paraffin-embedded specimen
histology, according to Keller and his colleagues.
Among plausible applications for MBVH could be enhanced
high-throughput analysis of possible side effects of drugs and effects
of exposure to environmental contaminants in preclinical toxicology
studies. Also feasible might be tumor vascular pattern analysis for
biopsies of tumors in patients who undergo anti-angiogenesis therapy.
Moreover, the NIH has launched a project to evolve knockout mice for
each of the 25,000 mouse genes. Given the large number of samples that
can be scanned simultaneously, MBVH technology could help speed up this
process.
Julian Josephson
Suggested Reading
Johnson JT, Hansen MS, Wu I, Healy LJ, Johnson CR, Jones GM, et al. 2006. Virtual histology of transgenic mouse embryos for high-throughput phenotyping. PLoS Genet 2(4):e61.
Ritman EL. 2004. Micro-computed tomography—current status and developments. Annu Rev Biomed Eng 6:185-208. [CrossRef].
Tyszka JM, Fraser SE, Jacobs RE. 2005. Magnetic resonance microscopy: recent advances and applications. Curr Opin Biotechnol 16(1):93-99.
Veith SJ. 2006. Virtual histology method bolsters visualization of mouse embryos. Biophotonics Int 13(7):24-25.